Cyber Resilience Act product categories: Default, Class I, Class II and Critical

Under the EU Cyber Resilience Act (Regulation (EU) 2024/2847), every product with digital elements must meet the essential requirements in Annex I and the reporting duties in Article 14. What changes by product category is the **conformity assessment route under Article 32**: whether you can complete internal control yourself (Module A) or must involve a notified body (Modules B+C, Module H, or a European cybersecurity certification scheme). This guide sets out the four categories and what to record in your technical file. It is documentation guidance, not legal advice.

Updated November 20, 2026

How Attesly keeps CRA evidence per product · Attesly plans and pricing

The four CRA product categories at a glance

Product categories and Article 32 conformity assessment routes in Regulation (EU) 2024/2847
CategoryLegal basisTypical examplesArticle 32 assessment route
DefaultNot listed in Annex III or Annex IVMost connected hardware, industrial devices, consumer IoT and commercial softwareModule A (internal control), Modules B+C, Module H, or a European scheme
Important — Class IArticle 7(1), Annex III Class IRouters, modems, switches, VPNs, password managers, operating systems, security-focused microprocessors/microcontrollers, smart home locks/cameras/alarmsModule A only if harmonised standards or common specifications are applied in full; otherwise Modules B+C, Module H or a European scheme
Important — Class IIArticle 7(1), Annex III Class IIFirewalls, intrusion detection/prevention systems (IDS/IPS), tamper-resistant microprocessors/microcontrollers, hypervisorsMandatory third-party assessment: Modules B+C (EU-type examination), Module H (full quality assurance), or a European scheme
CriticalArticle 8(1), Annex IVHardware security modules (HSMs), smartcards/secure elements, smart meter gatewaysEuropean cybersecurity certification scheme where mandated by delegated act; otherwise Class II routes

Core functionality decides — not incidental libraries

Article 7(1) ties classification to a product’s core functionality. Embedding a TLS library or connecting to a customer’s router does not turn an industrial sensor into an Annex III product. Conversely, if a device ships with an integrated router, gateway or security controller that forms part of its core purpose, assess that function explicitly against Annex III and Annex IV.

  • Check exclusions first (Article 2(2)–(4)): Medical devices, in-vitro diagnostics, motor vehicle type-approval, civil aviation and marine equipment follow their own sector rules.
  • Record your rationale: A dated scope and classification note in the technical documentation (Annex VII) shows market surveillance authorities why Module A or a notified body was chosen.
  • Watch harmonised standards for Class I: Chapter IV (notified bodies, Articles 35–51) has applied since 11 June 2026; full conformity assessment obligations apply from 11 December 2027 (Article 71(2)).

Module A vs. Modules B+C vs. Module H

  1. Module A (Internal control): Manufacturer completes the risk assessment, compiles the Annex VII technical documentation, verifies Annex I compliance and signs the EU declaration of conformity (Annex V) without a notified body.
  2. Modules B + C (EU-type examination + conformity to type): A notified body examines the technical design and issues an EU-type examination certificate; production units must conform to the approved type.
  3. Module H (Full quality assurance): A notified body assesses and audits the manufacturer’s quality system covering design, development, production and vulnerability handling.

What non-EU manufacturers should confirm with EU importers

Classification applies identically to manufacturers based outside the EU (US, UK, Taiwan, China, Japan and elsewhere) whenever a product is placed on the EU market. Under Article 19, EU importers must verify that the appropriate conformity assessment procedure was carried out and that the technical documentation, CE marking and EU declaration of conformity exist before placing the product on the market.

Keeping classification and evidence together in Attesly

In Attesly, each product record proposes a CRA category and Article 32 route that your team can override with its own written rationale. That decision sits next to your Annex I requirement statuses, imported SBOMs (CycloneDX, SPDX or CSV) with daily OSV/NVD checks, six structured document templates and Article 14 case tracking. Attesly does not perform conformity assessment or issue certificates. Related guides: CRA compliance checklist, Article 14 reporting and Annex VII technical documentation.

Frequently asked questions

Do Default products have fewer Annex I security requirements?

No. Annex I essential requirements, SBOM obligations, Annex VII technical documentation and Article 14 reporting apply across all in-scope categories. The category determines which Article 32 conformity assessment route is permitted.

Can a Class I product still use self-assessment (Module A)?

Yes, provided you apply the relevant harmonised standards, common specifications or European certification schemes in full (Article 32(2)). Otherwise third-party assessment under Modules B+C or H is required.

Does Article 14 reporting depend on the product category?

No. Since 11 September 2026, Article 14 reporting applies to all in-scope products with digital elements placed on the EU market, regardless of category.

Does Attesly certify products or submit conformity files to a notified body?

No. Attesly structures your product evidence, SBOM tracking and document drafts so your team and any external assessor can work from one versioned record.

How Attesly keeps CRA evidence per product · Attesly plans and pricing

Put your first product on file today.